SmartUSSING is a better way to increase the impact of your Ussing experiments by adding electrophysiological data. With an easy-to-use design, user-friendly software, and a smaller footprint, SmartUSSING makes electrophysiology easy and accessible for anyone.
With SmartUSSING, setup is a breeze, and there’s zero learning curve. Each amplifier is automatically calibrated by the software, meaning that no manual calibrations are necessary. Just plug it in, and you’re ready to go. Training is fast, easy, and painless – even if you’ve never done electrophysiological experiments before.
SmartUSSING is a vertical, multi-chamber Ussing system that supports measurements from native tissue, including from the stomach, large or small intestine, gallbladder or urinary bladder, skin, trachea, nasal epithelia, cornea, and more. It’s also an excellent solution for research on both primary and secondary cell monolayers from primary sources, including renal tubes, the pancreas, salivary or sweat glands, IPSCs, and immortalized cell lines (including CACO-2 and MDCKr).
With an easy setup and user-friendly software, SmartUSSING dramatically reduces the possibility for errors, meaning more accurate data and more reliable results.
SmartUSSING supports up to 6 chambers per holder, and up to 4 SmartUSSING systems can be connected to the same computer – giving you the flexibility to run up to 24 chambers in parallel. You can conduct up to 24 totally separate experiments at once, or maximize throughput by running up to 24 repetitions of the same experiment simultaneously. We offer flexible packages that allow you to purchase only the chambers you need.
SmartUSSING drastically reduces the amount of manual configuration and overall technical knowledge required to set up your amplifier and create recordings within your software program, making it significantly faster and easier to launch your experiments and analyze data. Our software, USSING Control, works so well for biologists because it was designed by biologists. With fast processing and a user-friendly interface, USSING Control makes data collection easier than any other program you’ll ever use.
While traditional USSING systems require a separate set of amplifiers and AD converters, SmartUSSING utilizes powerful miniature amplifiers mounted directly to the back of the chamber holder – meaning a 50% reduction in footprint, as well as easier setup, shorter cables, and less noise in your recordings. It’s a win-win.
Material | Acrylic |
---|
For all chambers not using culture cups:
Increase the tissue dimensions by a minimum of 3.0 mm in each direction
to allow the o-ring or pins to capture the tissue without tearing.
For example, a chamber with a 5 mm round aperture will require a tissue with a minimum diameter of 8 mm,
and a chamber with a 2 x 10 mm oblong aperture will require a tissue with minimum dimension of 5 x 13 mm.
Aperture | Applications | Aperture area | Volume range (per side) |
---|---|---|---|
4 mm round with pins | general use | 0.12 cm2 | 4-10 ml |
9 mm round with pins | general use | 0.34 cm2 | 6-14 ml |
4 x 8 mm oblong with pins | rat or larger intestine general use |
0.29 cm2 | 2.5-10 ml |
6 x 9 mm oblong with pins - Discontinued | rat and larger intestine general use |
0.46 cm2 | 4-12 ml |
5 x 24 mm oblong with pins | rat and larger intestine general use |
1.15 cm2 | |
8 x 24 mm oblong with pins | rat or larger intestine general use |
1.78 cm2 | |
Snapwell | cultured cells, cornea | 1.12 cm2 | 8-14 ml |
3 mm round, low volume, with pins | biopsy general use |
0.07 cm2 | 1-3 ml |
5 mm round, low volume, with pins | general use | 0.20 cm2 | 1.5-3 ml |
9 mm round, low volume, with pins | general use | 0.64 cm2 | 2-4 ml |
12 mm round, low volume, with pins | general use | 1.13 cm2 | 6-9 ml |
2 x 10 mm oblong, low volume, with pins | mouse intestine general use |
0.10 cm2 | |
4 x 8 mm oblong, low volume, with pins | rat or larger intestine general use |
0.28 cm2 | 1.5-3 ml |
Customers from Europe and Australia can use the Multi Channel Systems - Online Shop to order Warner products or create quotes.
Order No. | Model No. | Product Description | USA Price | Order |
---|---|---|---|---|
64-3126 | SmartUSSING Data Acquisition Interface (Rail) | Login | Login | |
64-3125 | SmartUSSING Epithelial Clamp (Amplifier) | Login | Login | |
Base Assembly | ||||
66-0075 | 6-Chamber heater block assembly (includes heating block, air/gas manifold, clear front panel, retaining ring clamp tool) | Login | Login | |
Standard Volume Navicyte Vertical | ||||
66-0014 | Standard Vertical Ussing/Diffusion Chamber, 9 mm diameter aperture, 0.64 cm2 area | Login | Login | |
66-0032 | Standard Vertical Ussing/Diffusion Chamber, 4 x 8 mm aperture, 0.29 cm2 area | Login | Login | |
66-0046 | Standard vertical Ussing/diffusion chamber, 5 x 24 mm aperture, 1.15 cm2 area | Login | Login | |
66-0013 | Standard Vertical Ussing/Diffusion Chamber, 8 x 24 mm aperture, 1.78 cm2 area | Login | Login | |
Low Volume NaviCyte Vertical (includes electrode screws) | ||||
66-0040 | Low volume vertical ussing/diffusion chamber, 3 mm diameter aperture, 0.07 cm2 area | Login | Login | |
66-0026 | Low volume vertical ussing/diffusion chamber, 5 mm diameter aperture, 0.20 cm2 area | Login | Login | |
66-0015 | Low volume vertical ussing/diffusion chamber, 9 mm diameter aperture, 0.64 cm2 area | Login | Login | |
66-0027 | Low volume vertical ussing/diffusion chamber, 12 mm diameter aperture, 1.13 cm2 area | Login | Login | |
66-0034 | Low volume vertical ussing/diffusion chamber, 2 x 10 mm aperture, 0.10 cm2 area | Login | Login | |
66-0042 | Low volume vertical ussing/diffusion chamber, 4 x 8 mm aperture, 0.28 cm2 area | Login | Login | |
Specialty | ||||
66-0008 | Specialty Vertical Ussing/Diffusion chamber, Snapwell, 1.13 cm2 | Login | Login | |
66-0020 | Electrode Cap for Snapwell chambers, L/R pair | Login | Login | |
Chamber Caps | ||||
66-0018 | Electrode Cap for standard volume chamber , L/R pair | Login | Login | |
66-0019 | Perfusion Cap for standard volume chamber , L/R pair | Login | Login | |
66-0020 | Electrode Cap for Snapwell chambers, L/R pair | Login | Login | |
Electrodes and Components | ||||
66-0023 | Ag/AgCl electrodes with KCl, 100 cm leads, 4 pack (sufficient for 1 chamber) | Login | Login | |
66-0024 | Glass barrel for Ag/AgCl electrode, with ceramic tip, 8 pack | Login | Login | |
66-0049 | Open screws with o-rings for low volume chambers. Serves as electrode holders, 12 pack | Login | Login | |
Thermocirculator | ||||
64-2244 | WB-KIT | TC-120 Thermocirculator Tubing Kit | Login | Login |