It supplies up to 22 watts into a load of 10 ohms. Heat set-point is controlled automatically in Auto mode via thermistor feedback. A loop-speed selector provides three feedback response times to optimize tp the thermal stability of the device being heated. Heat set-point may also be manually controlled in Manual mode.
Ease of Use
In Auto mode, the desired temperature is set with a single set temperature control. The connected platform, solution heater, or other device is automatically maintained at the set temperature. Accuracy is typically better than ± 1°C, and under ideal conditions will approach ± 0.1°C. In Manual mode, the controller provides a continuous DC output adjustable from 0 to +15 volts.
Quiet Operation in Recording Setups
Highly filtered DC power supplies employing toroidal transformers are used to eliminate AC noise and deliver the high-level of isolation required for sensitive electrophysiology applications. Slow-ramped analog switching circuitry delivers power without adding noise to the system.
Unique Features
An open-thermistor fault protection circuit prevents overheating of the sample in the event of a thermistor failure. Remote control of the set temperature allows a computer to control the sample temperature.
Thermistor Readouts
Each channel reads two thermistors simultaneously: T1 for feedback control of the system, and T2 for measurement of any point of interest. These temperatures are displayed on the meter and are also available at front and rear panel outputs for recording devices. Unical thermistors are used and can be replaced without the need for recalibration.
Specifications
Maximum Output Voltage | 15 VDC |
---|---|
Maximum Output Current | 1.5 A |
Minimum Load Resistance | 10.0 Ω |
Manual Voltage Range | 0.0 to 15.0 VDC |
Maximum Output Power | 22 W into a 10 Ω load |
Power Requirements | 95-130 or 200-260 VAC, 50/60 Hz |
Power Fuse | (5x20 mm) 0.5A SB for 95-130 VAC and 0.25A SB for 200-260 VAC |
Front Panel BNC | Input/Output T2 thermistor Reporting 100 mV/°C |
Rear Panel BNC | Output T1 (control) Reporting 100 mV/°C |
Temperature Range | Ambient to 65°C |
Internal Set Temperature | 22°C to 65°C |
External Set Temperature | Ambient to 65°C |
Meter Display | 3.5 digit LED display of °C or V |
Meter Readouts | Set temperature T1 (control) temperature T2 (monitor) temperature Output voltage (to heater) |
Enclosure (W x H x D) | 43.2 x 8.9 x 30.5 cm (17.0 x 3.5 x 12.0 in) |
Weight | 5.44 kg (12 lb) |
Warranty | Two years, parts & labor |
(TC-344C) Dual Channel Temperature Controller
Heating and Cooling: Application Fundamentals
(SH-27B, SF-28) Single Inline Solution Heaters
PM Series Magnetic Heated Platforms
PH Series Heated Platforms
(QE-1) Quick Exchange Platform for 35-40 mm dishes
Platform Interface Cables, Thermistors, & Replacement Parts
Customers from Europe and Australia can use the Multi Channel Systems - Online Shop to order Warner products or create quotes.
Order No. | Model No. | Product Description | USA Price | Order |
---|---|---|---|---|
Temperature Controllers | ||||
64-2400 | TC-324C | Heater controller, single channel, 110-230 VAC, 50/60Hz | Login | Login |
Heating Accessories | ||||
64-0102 | SH-27B | In-line solution heater | Login | Login |
64-1555 | SHH-1 | Holder for SH-27B and SF-28 inline solution heaters | Login | Login |
64-0103 | SF-28 | Slow flow in-line solution heater | Login | Login |
Cables | ||||
64-0106 | CC-28 | Cable assembly for heater controllers to platform | Login | Login |
64-0107 | TA-29 | Cable with bead thermistor | Login | Login |
64-0108 | TA-30 | Cable with glass thermistor | Login | Login |
64-0109 | CC-35 | Cable assembly for heater controllers, unterminated with tinned leads at platform end | Login | Login |
Replacement Parts | ||||
64-0270 | TS-70B | Replacement bead thermistor for CC-28 Cable | Login | Login |
64-0274 | RH-2 | Heater elements for Warner chambers and platforms, 2 pack | Login | Login |